Industrial Power
Click the link below to download the file.
Get your files as below link
Dowload link
24V
200W
8.33A
90-264Vac
113.9 x 64.7 x 44.7 mm
4.48” x 2.55” x 1.76”
0.345 kg (0.76 lb)
** NRND **
Recommended Model:
MEP-200A24J CNA
** NRND **
Recommended Model:
MEP-200A24J CNA
24V
200W
8.33A
90-264Vac
113.9 x 64.7 x 44.7 mm
4.48” x 2.55” x 1.76”
0.345 kg (0.76 lb)
Output Current
8.33A
|
Output Voltage
24V
|
Output Voltage Range
|
Output Voltage Adjustment Range
-
|
Output Power
200W
|
Output Current Adjustment Range
|
Max Output Voltage
|
Buffering Time
-
|
Line Regulation
±0.5%
|
Load Regulation
±1%
|
PARD
-
|
Start-up Time
2000ms @ 115Vac
|
Hold-up Time
12ms@115Vac, tested with 120W load
|
Dynamic Response (Overshoot & Undershoot O/P Voltage)
± 5% @ with 50-100% load
|
Start-up with Capacitive Loads
-
|
Remote ON/OFF
-
|
Protective Device
-
|
Voltage Drop Between Input and Output
-
|
Residual Ripple/PARD (20MHz)
-
|
Residual Ripple
-
|
Max. Power
-
|
Ripple & Noise
-
|
LED System Voltage Range in CC Mode
-
|
Rise Time
100ms
|
Power Boost Duration
-
|
Power Boost Recovery Time
-
|
Nominal Input Voltage
100-240Vac
|
Input Voltage Range
90-264Vac
|
Max Input Voltage
-
|
Nominal Input Frequency
50-60Hz
|
Input Frequency Range
47-63Hz
|
Nominal DC Input Voltage
|
DC Input Voltage Range
-
|
Input Current
2.5A
|
Input Power (Standby Mode)
-
|
Efficiency at 100% load
92% @ 115Vac/60Hz
93% @ 230Vac/50Hz, Reference |
Inrush Current
60A@230Vac, cold start
|
Charging Time
-
|
Power Factor at 100% load
0.95 @ 115V/50Hz, 230V/50Hz, full load
|
Leakage Current
-
|
Nominal Current
-
|
Total Harmonic Distortion
-
|
Power Dissipation
-
|
Efficiency @ 10% load
-
|
Case Chassis / Cover
Enclosed cover(SPCC)
|
|
Indicator
-
|
|
Cooling System
-
|
|
Input Terminal
-
|
|
Output Terminal
-
|
|
Signal Terminal
-
|
|
Noise Sound Pressure Level (SPL)
-
|
|
Input/Output Terminal
-
|
|
Signal
-
|
|
Mounting Rail
-
|
|
Wire
-
|
|
Protection Structure
-
|
|
Terminal
-
|
|
Unit Weight
0.345 kg (0.76 lb)
|
Dimensions
113.9 x 64.7 x
44.7 mm
4.48” x 2.55” x 1.76” |
Vibration (Operating)
5-500Hz, 2Grms, 15 minute for each three axis
|
Shock Test (Operating)
-
|
Operating Temperature
Absolute Max
-10°C to+70°C, supported powerlinearly de-rate from 50°C to 50% ratedup to 70°C Note: see power de-rating curve |
Storage Temperature
-40°C to +85°C
|
Power De-rating
Linearly derate from 100% load at 50°C, to 50% load at 70°C (2.5%/ degree centigrade)
|
Operating Humidity
5-95% RH (Non-Condensing)
|
Shock Test (Non-Operating)
50G, 11ms, 3 shocks for each direction
|
Vibration (Non-Operating)
-
|
Storage Humidity
-
|
Operating Altitude
5,000 meters (16402 feet)
|
Pollution Degree
-
|
Bump Test (Operating)
-
|
Over Voltage Category
-
|
Corrosion
-
|
Overvoltage
125% of rated voltage, Latch Mode
|
Overload / Overcurrent
Main output 160% of rated current
Hiccup Mode(Non-Latching, Auto-Recovery) |
Over Temperature
Latch Mode
|
Short Circuit
Hiccup Mode, (Non-Latching, Auto-Recovery)
|
Reverse Polarity Protection
-
|
Degree of Protection
-
|
Protection Against Shock
-
|
Input Polarity Protection
-
|
Battery Polarity Protection
-
|
Wrong Battery Voltage Protection
-
|
Deep Discharge Protection
-
|
Overload
-
|
Overcurrent
-
|
Internal Fuse
-
|
Insufficient Input Voltage Protection
-
|
MTBF
800 Khrs based on Telecordia SR-332
|
Expected Cap Life Time
Operating life at 115Vac, 110W, ambient 25 °C, Convection Air Flow: 26,280Hrs
|
Safety Certificate
IEC60950-1, IEC62368-1 CB report
TUV60950-1 UL60950-1+CAN/CSA60950-1 |
Electrical Safety
-
|
CE
In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU
EN 60601-1: 2006 + A11: 2011 + A1L 2013 + A12: 2014 & EN 60601-1-2: 2015 |
Medical Safety
IEC 60601-1 CB report
TUV EN 60601-1 UL 60601-1+CAN/CSA 60601-1 |
Galvanic Isolation
Input to/Output (2XMOPP): 4000 Vac
Input to/Ground(1XMOPP): 1500Vac(PSU can support PoE applications with Primary to FG 2500Vac test.) Output to/Ground(1XMOPP): 1500Vac ( Type BF application rated) |
Industrial Control Equipment
-
|
Hazardous Location / ATEX
-
|
II 3 G ATEX 2014/34/EU
-
|
Electrical Equipments of Machines
-
|
Electrical Equipment for Use in Electrical Power Installations
-
|
Safety Entry Low Voltage
-
|
Maritime
-
|
Material and Parts
-
|
Isolation Resistance
-
|
PE Resistance
-
|
UKCA
In conformance with Electrical Equipment (Safety) Regulations 2016 and Electromagnetic Compatibility Regulations 2016, Medical Devices Regulations 2002 (UK MDR 2002)
|
Certificates for Other Countries
-
|
BIS
-
|
KC
-
|
Electrical Equipment for Measurement, Control, and Laboratory Use
-
|
ITE Safety
IEC 60950-1, IEC 62368-1 CB report
TUV 60950-1 UL 60950-1+CAN/CSA 60950-1 |
SIL3
-
|
Emission
Class I model: EN/BS EN 55011, EN/BS EN 55022, FCC Title 47: Class B
|
Immunity
-
|
Harmonic Current Emissions
IEC 61000-3-2 Meet Class D limit
|
Voltage Fluctuation and Flicker
IEC 61000-3-3
|
ESD Immunity
-
|
Radiated Immunity
-
|
EFT
-
|
Surge
-
|
Conducted Immunity
-
|
Magnetic Field
-
|
Voltage Dips
-
|
Component Power Supply for General Use
-
|
24V
2500W
104.2A
85-264 Vac
24V
2000W
83.3A
80 - 275 Vac
48V
200W
-
90-264 Vac
48V
2000W
41.6A